热门新闻
Torque Control is one of the less widely understood layers of industrial drive control, and the confusion is understandable. A drive running in speed mode is asked a simple question: how fast should the motor turn. A drive running in torque mode is asked a different and harder question: how much effort should the motor produce, and the machine answers by moving, gripping, tightening, pressing or loading. That indirect feedback loop - effort commanded, movement produced - is the source of both the usefulness and the difficulty of torque control.
In its simplest form a torque controller regulates motor current, because in the linear operating range of an induction or permanent magnet servo motor, torque is proportional to current. The controller compares a commanded torque with a measured or estimated torque and adjusts the current accordingly. The measured side may come from a torque transducer on the output shaft, from motor current and rotor position combined through a motor model, or from a simpler open-loop current reference with a feed-forward term for friction and load inertia.
The distinction between these three approaches determines almost everything that follows. A system with a shaft-mounted torque transducer measures the actual output effort and can correct for losses downstream of the motor. A system using a motor model estimates torque from current and position, which is cheaper and faster but cannot see compliance in the coupling, wear in a gearbox, or a process force applied downstream. An open-loop current reference is the least precise and the most sensitive to mechanical condition.
Torque control is chosen wherever the process variable is force rather than motion. The applications below are typical, and the control mode they need varies with the accuracy demand and the mechanics of the machine.
| Application | What is being controlled | Typical control approach |
|---|---|---|
| Nutrunner and bolting | Clamping force at a joint | Torque mode with angle monitoring as a cross-check |
| Winding and unwinding | Constant tension in the web | Torque reference derived from dancer or load cell |
| Press and clamp | Force at a defined stroke | Torque control through a stiff drivetrain, or force transducer control |
| Cable and pipe pulling | Constant pull force | Torque mode with slip monitoring |
| Test stands and dynamometers | Constant load at varying speed | Torque mode with closed-loop transducer feedback |
The pattern is consistent. Where the reaction force is known only through the drivetrain, torque mode with a good motor model is usually enough. Where accuracy matters in absolute terms - a joint that must reach a specified preload, a web that must not stretch - a real force measurement closes the loop properly.
Choosing the wrong mode is a common cause of disappointing results, so the differences are worth stating plainly.
| Aspect | Speed mode | Position mode | Torque mode |
|---|---|---|---|
| Controlled variable | Rotational speed | Angular or linear position | Output effort |
| Feed back from | Encoder or sensorless estimate | Encoder | Torque transducer or motor model |
| Typical use | Conveyors, fans, pumps | Robots, CNC, indexing | Tightening, winding, pressing |
| Main risk | Speed runaway if load is removed | Following error, lost steps | Drift, oscillation, thermal growth in couplings |
| Stiffness concern | Low | High | Medium, depends on sensor loop speed |
One practical note on safety: in torque mode the load can run away when the resistance it is pushing against disappears. Any machine that runs a torque-controlled axis should have a defined limit on maximum commanded torque and a mechanical means of arresting the load, because the electronic limit alone is not a safety device.
Commissioning should proceed in a fixed order, and each stage should be signed off before the next begins. Start with the motor and feedback: confirm the motor nameplate data against the drive configuration, confirm the encoder and any torque transducer are responding plausibly at standstill, and check the wiring of the transducer against the manufacturer's pinout, including the supply voltage for the sensor bridge.
Next, verify direction and sign conventions. Run the axis unloaded at a low torque command and confirm that the response has the correct sign; a reversed sign convention shows up later as a control loop that hunts violently at the first load application. Then apply a modest, bounded torque command and check that the measured output follows it in the expected proportion, adjusting the gain that maps torque command to current if it does not.
Only after the loop is stable at low command levels should the process conditions be introduced - actual speed, actual load, and the real mechanics of the machine.
A torque loop is typically faster than the surrounding mechanical system, and that is where its stability comes from: the electronics respond quickly while the drivetrain filters the disturbance. As the torque loop gain rises, the loop starts to fight the compliance in the coupling and gearbox, and oscillation appears. Tuning therefore trades response speed against stability, and the useful discipline is to raise gain until oscillation appears, back off until it settles, and repeat.
Practical tuning sequence:
The filter settings on the measured feedback channel deserve the same attention as the loop gain. A filter that is too aggressive smooths the signal but adds phase lag, and phase lag in the feedback path is precisely what turns a stable loop into an unstable one.
Even a perfectly tuned loop reports the wrong number if the mechanics do not match the model. Torque lost in the coupling, the gearbox and the bearings does not reach the process, so a model-based estimate will overstate the force applied. The error grows with load, which is why a system can look accurate at light load and drift badly at full load.
Other contributors include bearing preload that changes with temperature, a gearbox whose backlash opens under load reversals, a twisted shaft that stores energy and releases it during direction changes, and belt or coupling wear that changes the effective ratio. Checking these items during troubleshooting is essential, because a controller cannot compensate for a drivetrain that is changing under it.
Torque sensors must be installed so that they measure the torque that matters. A sensor mounted between the motor and a gearbox measures motor-side torque, not the force delivered to the process after gearbox losses. If the process cares about the output, the sensor belongs at the output, or the losses must be characterised and modelled. This single placement decision explains many discrepancies between a wrench reading and a controller reading.
Sensor health also has to be verified, not assumed. A bridge-based sensor drifts with temperature and can saturate if the mechanical shock exceeds its rating. Check the signal baseline at known zero load, confirm the excitation voltage, confirm the polarity, and confirm that the signal stays inside the linear range at maximum load. A noisy measurement looks exactly like a badly tuned loop, and the two are confused often enough that the sensor should be checked first.
Working from symptoms is more reliable in the field than working from the code list, because most torque control problems never produce a hard alarm.
| Symptom | Likely causes | First checks |
|---|---|---|
| Output torque drifts with time | Sensor thermal drift, coupling creep, bias drift in the model | Zero-load baseline over time, temperature at the sensor, load-dependent error check |
| Oscillation at high gain | Loop gain too high, filter lag, mechanical resonance | Step test at low load, verify filter settings, check drivetrain for looseness |
| Reading below the process value | Sensor positioned on the wrong side of the gearbox, unmodelled losses | Compare with a wrench or dynamometer reading, map loss curve against load |
| Unable to hold torque at standstill | Brake not engaged or worn, drive in wrong mode, output slipping | Confirm mode and brake state, inspect the mechanical load for slip |
| Fault only under fast direction reversals | Twisted shaft storing energy, backlash, drive ramp settings too abrupt | Slow the reversals and re-test, check ramp and jerk limiting |
The first check in most of these cases is the cheapest one: reproduce the condition with the load reduced and see whether the symptom changes proportionally. A symptom that disappears at light load points to mechanics or sensor issues; one that persists points to configuration or control.
Because torque control commands force directly, limits belong in the controller rather than in the operator's judgement. Configure a maximum torque that cannot exceed the structural limit of the machine, a speed limit that prevents runaway if the load suddenly disappears, and a timeout that drops to a safe state if the measured feedback stops updating.
Long-term drift is the normal enemy of accuracy. Re-check the zero-load baseline on a routine schedule, track the difference between the controller reading and an independent measurement, and treat a growing gap as a maintenance trigger for bearings, couplings and sensor mounting. Records of that gap over time are what allow slow degradation to be caught before it becomes a quality complaint.
Torque Control works when the loop, the sensors and the mechanics are treated as one system. Commission in stages - feedback, sign convention, low-level loop stability, then real process conditions - and tune the loop for stability before adding feed-forward and process shaping. When a fault appears, reproduce it at reduced load, verify the sensor baseline and the mechanical path before touching tuning parameters, and keep the limits that protect the machine in the controller rather than in operating habit. With that discipline, torque control delivers force that is repeatable and traceable, and the troubleshooting that follows a fault is a sequence of checks rather than a search.