销售服务热线:

Servo Motor Selection: Torque, Inertia and Encoder Feedback Compared

A servo motor rarely fails for the reason operators expect. It is usually asked to deliver torque it cannot sustain at the speed the machine actually runs, or to move an inertia load that turns every cycle into a thermal problem.

Below is a repeatable method for servo motor selection that works across conveyors, packaging lines, machine tools and robotics. The order of steps matters: define the load, read the torque-speed curve, check the inertia relationship, then match feedback and mechanical options.

Why Servo Motor Selection Sets the Limits of the Machine

A servo motor converts electrical energy into controlled rotary motion, but its usefulness is defined by the envelope the manufacturer publishes. Rated torque, peak torque, maximum speed, rotor inertia and thermal limits are the boundaries of the working area.

Because that envelope is fixed at purchase, selection mistakes are expensive later. Replacing an undersized motor means new cables, new drive settings, new mounting hardware and a fresh commissioning cycle.

  • Torque decides whether the load can be moved, and for how long.
  • Speed decides whether the cycle time target is reachable.
  • Inertia decides how fast the axis accelerates and stops cleanly.
  • Thermal capacity decides whether the motor survives a full shift.
  • Feedback and mechanical options decide how the motion behaves.

Start With the Load, Not the Catalogue

The most common failure in servo motor selection is to browse available motors first and look for a duty cycle afterwards. Reverse the order. Write down what the axis does: the mass it moves, the direction of travel, the distance, the number of moves per minute and the duty across a full shift.

From those numbers, calculate the torque required at the lowest speed in the cycle. For a rotating load, torque is the force at the radius divided by that radius. For a linear load, divide the linear force by the pitch radius of the pulley or rack. Add friction losses, and for a vertical axis add the torque needed to raise the load.

Working conditionDominant torque demandWhat to check first
Steady horizontal transportConstant load torqueGuide friction, belt losses
Accelerating horizontal massAcceleration plus load torqueReflected inertia, move time
Vertical lift at constant speedGravity torque held continuouslyLoad mass, brake requirement
Vertical loweringGravity drives the motorBrake release timing
Short-cycle positioningPeak torque in accelerationMotion profile, moves per minute

The table separates conditions that are often confused. Constant speed transport is sized on load torque alone, while positioning axes are usually sized on acceleration torque, which can be several times larger. If the calculated peak approaches the published peak rating, the axis needs a larger frame or a more conservative ratio.

Reading the Torque-Speed Curve

The torque-speed curve is the most informative graphic on a servo motor datasheet and the one most often ignored. It shows rated and peak torque across the speed range and usually marks the continuous operating region. Above a certain speed the motor can no longer dissipate the losses generated at full torque, so rated torque falls while peak torque may remain available in short bursts.

Three rules follow. Size the motor at the speed where the axis spends most of its cycle. Treat peak torque as a time-limited allowance. Confirm that the required continuous point sits inside the marked region.

Motor power classRated torquePeak torqueRated speedRotor inertia
Fractional, up to 0.75 kW0.6 to 2.4 Nm1.8 to 7.2 Nm1500 to 3000 rpm0.3 to 1.2 kg cm2
Mid range, 1 to 2 kW3.2 to 6.4 Nm9.6 to 19.1 Nm1500 to 3000 rpm1.5 to 4.0 kg cm2
Upper mid range, 3 to 5 kW9.5 to 15.9 Nm28.6 to 47.7 Nm1500 to 3000 rpm4.0 to 9.0 kg cm2

These are indicative ranges for typical industrial families rather than catalogue data. The useful pattern is the ratio between peak and rated torque, commonly near three to one, and the way rated torque tapers near base speed.

Continuous and Peak Torque Ratings

Two ratings dominate every servo specification sheet. Continuous or rated torque describes what the motor can deliver indefinitely without exceeding its permitted winding or bearing temperature. Peak torque describes a short overload that the drive may permit under defined conditions.

The distinction matters most on axes that accelerate and stop frequently. A pick-and-place arm demands torque in brief bursts, so the peak rating governs the design. Quoting a peak rating where a continuous rating is needed produces a motor that runs hot and trips its thermal protection.

RatingWhat it measuresUse in selection
Continuous torqueTorque sustainable within temperature limitsBaseline for steady and cyclic duties
Peak torqueShort overload within drive limitsAcceleration and reversing
Maximum speedHighest safe speed at rated torqueConfirming the cycle time target
Thermal protectionTemperature that triggers a faultDefining the continuous band

Inertia Matching and the Acceleration Limit

Inertia is the hidden variable in servo motor selection. A motor can produce enough torque and still fail to deliver the cycle time if the load has far more inertia than the rotor can manage. The ratio between load inertia reflected to the motor shaft and rotor inertia is the usual reference point.

Add the inertia of every rotating element and translate moving mass into an equivalent at the motor shaft. Where a gear reducer is fitted, the reflected inertia is the load inertia divided by the square of the reduction ratio, while the motor side inertia is multiplied by the same ratio.

QuantitySymbolValue usedNote
Moving mass on the carriagem50 kgHorizontal axis
Driven pulley pitch radiusr0.05 mConverts force into torque
Guide and seal friction factorf0.05Typical for guides
Gear ratio at the motori20Multiplies torque
Steady torque at the motorT0.06 NmFrom force, radius, ratio
Reflected load inertiaJ3.1 kg cm2Over the square of ratio
Motor rotor inertiaJo0.84 kg cm2750 W class motor

The worked figures show a typical result: steady running torque is tiny next to the rated torque of the motor, so the axis is acceleration limited rather than load limited. As a rule of thumb, keep reflected load inertia within roughly ten times rotor inertia for general machinery.

Comparing Servo Motor Families

Servo motor selection often means choosing between families rather than between sizes. The mainstream choices are AC brushless servo motors, DC motors in older or cost-driven designs, and stepper systems, which are technically open loop drives but occupy a similar price band.

The practical differences are torque at speed, the need for feedback and the commissioning effort. A stepper holds position at standstill without a sensor, but available torque falls as speed rises. An AC servo holds torque across the rated speed band because rotor position is measured directly and the drive corrects the error continuously.

AttributeAC servo motorStepper motorDC motor
Position feedbackEncoder as standardUsually noneEncoder or tachometer
Torque at speedMaintained across bandFalls as speed risesModerate
Holding at standstillCurrent or shaft brakeFull holding torqueNeeds current
RepeatabilitySet by encoder and tuningGood at low speedModerate
Efficiency runningHighLow to moderateModerate

Encoder Feedback and Resolution Choices

Feedback is what turns a motor into a servo. An encoder reports rotor angle, and the drive compares that angle with the commanded position to generate a correction. The resolution of that measurement determines how finely the machine holds position and how the axis behaves at low speed.

Incremental encoders output pulses per revolution and rely on a homing reference to establish absolute position after power-up. Absolute encoders store position inside the device, so the machine knows where it is immediately. For machine tool feeds and robotics, absolute feedback with a high bit count is normally preferred.

Feedback typeTypical resolutionAbsoluteTypical application
Incremental, standard1024 to 2500 pulsesNoConveyors, indexers
Incremental, high resolution4096 pulses and aboveNoFeed axes with home sensor
Absolute, single turn17 to 21 bitsWithin one turnModular short travel axes
Absolute, multi turn21 to 23 bitsIncluding turnsScrew or belt drives

Mechanical Options That Decide Whether the Motor Fits

Electrical specification is only half of servo motor selection. The mechanical envelope decides whether the motor physically fits and whether it survives the environment. Flange dimensions, shaft diameter, shaft length with keyway and cable entry direction are fixed at order time.

A shaft mounted brake is the option most often specified too late. A brake is needed on vertical axes so the load cannot fall when power is removed, and on any axis where a power loss becomes a safety hazard. The drive must release the brake only when it can hold the load, otherwise the motor fights the brake and reports an overload.

FactorWhy it mattersAction during selection
Flange and shaft sizeDecides fit with the bracketCheck the drawing
Shaft mounted brakeHolds a load after power lossSpecify the release sequence
Protection ratingResistance to dust and waterMatch the real environment
Ambient temperatureReduces continuous torqueRequest the derating curve
Feedback connectorMust match drive and cableConfirm the encoder type

Matching the Motor to the Drive and the Machine

A servo motor is only half of a servo system. The drive determines the current in the windings, the voltage available at high speed, the loop behaviour and which feedback device can be connected.

Check the electrical side carefully. Servo drives are supplied for single phase or three phase supply within a voltage range, and the drive current ratings map directly onto motor torque. A drive that is consistently overloaded may allow the motor to be overdriven.

CheckQuestionEvidence to request
SupplyWhat voltage and phases are accepted?Drive input specification
CurrentDoes drive current cover rated torque?Drive and motor currents
FeedbackWhich encoders can be connected?Compatibility list
Command sourceHow will the axis be commanded?Interface list and update rate
RegenerationCan returned energy be absorbed?Brake resistor or regen option

Mistakes That Appear After Commissioning

Most selection errors are not dramatic. They surface weeks later as a machine that runs slightly hot, an axis that overshoots at the end of a move, or a drive that trips on overcurrent during a cold start.

  1. Sizing on peak torque alone. The continuous rating then fails on a long shift.
  2. Ignoring the torque drop at speed. The motor meets the need at low speed only.
  3. Leaving inertia uncalculated. The result is low stiffness and long settling.
  4. Forgetting the gearbox in the inertia calculation. Reflected inertia changes with the square of the ratio.
  5. Omitting the brake from the specification. Vertical axes are machined first.
  6. Specifying feedback too late. The encoder type decides the drive and the cable.

Conclusion

Servo motor selection rewards a disciplined order of operations. Define the load and the duty cycle, calculate the torque at the speed the axis actually works at, read the torque-speed curve, check the inertia relationship against the real motion profile, then choose feedback, mechanical options and a supporting drive.

A selection made that way usually sits inside the continuous operating band with margin at both ends, and it is a motor that can be commissioned quickly, tuned without fighting the mechanics and left running for years without thermal surprises. For buyers comparing quotations, published torque-speed data is usually more revealing than the headline power rating.

2026/11/13 13:30:00 32 次